3D feature constrained reconstruction for low-dose CT imaging
Abstract—Low-dose computed tomography (LDCT) images are often highly degraded by amplified mottle noise and streak artifacts. Maintaining image quality under low-dose scan protocols is a well-known challenge. Recently, sparse representation-based techniques have been shown to be efficient in improving such CT images. In this paper, we propose a 3D feature constrained reconstruction (3D-FCR) algorithm for LDCT image reconstruction. The feature information used in the 3D-FCR algorithm relies on a 3D feature dictionary constructed from available high quality standard-dose CT sample. The CT voxels and the sparse coefficients are sequentially updated using an alternating minimization scheme. The performance of the 3D-FCR algorithm was assessed through experiments conducted on phantom simulation data and clinical data. A comparison with previously reported solutions was also performed. Qualitative and quantitative results show that the proposed method can lead to a promising improvement of LDCT image quality.